Hitachi DK326C SCSI Hard Drive

View of the DK326C PC Board.

Default settings are or in Bold.
View of J6.

J6(1/2),(3/4),(5/6): SCSI ID

  • (1/2): SCSI ID#1
  • (3/4): SCSI ID#2
  • (5/6): SCSI ID#4
  • J6(7/8): LED

    View of J7.

    JP2(1/2),(3/4) or J7(1/2),(3/4): Spindle Sync.

  • Factory Default Setting:(1/2) & (3/4) Jumpered: Off Line.
  • Optional Setting:(1/2) Jumpered: Master.
  • Optional Setting:(3/4) Jumpered: Slave.
  • Optional Setting:Both Open: (Not Specified).
  • JP2(5/6): Spin-Up Option

  • Default Setting:Jumpered: Spin-up at Power On.
  • Optional Setting:Open: Spin-up on SCSI Command.
  • JP2(7/8): SCSI Parity

  • Optional Setting.Jumpered: SCSI Bus PArity Checking Disabled.
  • Default Setting.Open: SCSI Bus Parity Checking Enabled.
  • (9/10),(11/12),(13/14),(15/16): Factory Installed (Do not remove)

    J3(1/2),(3/4): Termination Power Source

  • Default Setting:(1/2) Jumpered: Term. Power supplied from the Drive.
  • Optional Setting:(3/4) Jumpered: Term. Power supplied from the SCSI Bus.
  • J3(5/6): SCSI Bus Terminator

  • Jumpered: Enable the Terminator.
  • Open: Disable the Terminator.
  • JP3(7/8): Sync. Spindle Terminator

  • Default Setting:Jumpered: Master Clock line is Terminated.
  • Optional Setting:Open: Master Clock line is not Terminated.

  • | DK326C-6 | DK326C-10 | Feedback | Jargon |